| Peer-Reviewed

Applications to Engineering Physics for Reducing Air Pollution

Received: 2 September 2015     Accepted: 19 September 2015     Published: 14 October 2015
Views:       Downloads:
Abstract

Taking advantage of modern technology of the macro ionization of air in the air conditioning systems in order to promote the industrial air conditioning systems can be an appropriate way to resolve industrial centers and hospital's pollution, and also resolve monitoring of air in the urban tunnels. Breathing space around us is a mixture of particles and neutral and charged molecules, so by looking back at industrial achievements of tools and instruments of the air conditioners, electrical discharge method is practical and appropriate. In addition to refining of air pollutants, there is also the possibility of removing germs. Macro Air Ionization Technology (MAIT) in the industrial, hospital and urban tunnels is one of the offering methods of increasing healthy air as usual methods in environment. MAIT is a hi-tech equipment for improving air. One of these technologies is Negative Air Ionization Technology (NAIT). In the NAIT equipment air molecules after ionization change Negative Ion Concentrations in the room, tunnels and sheds. The negative ion molecules especially oxygen, will provide a healthy environment for plants growth process. Using NAIT, anions have the ability to conquest the microbes and microorganism. According to the performed research, utilizing the air ventilation modern technologies, have an efficient effect on the quantity and quality of important place as hospitals. For this reason, negative ion injections by MAIT into the air could be a part of research policies in developing and least developing countries for effective exploitation and correction of the Health and Safety Executive (HSE) conditions, as it was the part of basic research policies in last 40 years in developed countries. In this paper, we try to introduce hi-tech MAIT equipment based on corona discharge method.

Published in Science Innovation (Volume 3, Issue 6)
DOI 10.11648/j.si.20150306.19
Page(s) 117-120
Creative Commons

This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2015. Published by Science Publishing Group

Keywords

Air Ionization, Corona Discharge, Airborne, Antimicrobial Infections, Healthy Air

References
[1] Chen, J., Davidson, J. H., “Electron density and energy distributions in the positive DC corona: Interpretation for corona-enhanced chemical reactions”, Plasma Chemistry and Plasma Processing, 22. 199-224. 2002.
[2] Zhao, L., Adamiak, K., “EHD flow in air produced by electric corona discharge in pin-plate configuration”, Journal of Electrostatics, 63(3-4). 337-350. 2005.
[3] Jahanshir A., et al., “Mechanism of Corona Discharge Process and Reducing Effects on Urban Air Pollution”, National Conference on Air Pollution Monitoring, Effects and Controlling Actions, Science and Research Branch of Islamic Azad University, Ahwaz, Iran, 110-116. 2013.
[4] Jahanshir A., “Artificial Injection of Charged Particles and Reducing Concentration of Dust and Pollution”, National Conference on Air Pollution Monitoring, Effects and Controlling Actions, Science and Research Branch of Islamic Azad University, Ahwaz, Iran, 56-63. 2013.
[5] Jahanshir A., “Artificial Air Ionization Process in Reducing Gas Pollutions”, National Conference on New Technologies in Controlling of Environmental Pollutions, Sharif Technical University, Tehran, Iran, 95-100. 2013.
[6] Tyagi, AK, Malik, A., “Antimicrobial action of essential oil vapours and negative air ions against Pseudomonas fluorescens”, International journal of food microbiology, 143(205). 10. 2010.
[7] Hirsh, H., Coen, M. H., Mozer, M. C., Hasha, R. and Flanagan, J. L, “Room service, AI-style,” IEEE intelligent systems, 14 (2). 8-19. Jul.2002.
[8] Kellogg, E. W, Yost, M. G, Barthakur, N., Kreuger, A. P., “Superoxide involvement in the bactericidal effects of negative air ions on Staphylococcus albus”, Nature, 281(400)1. 1979.
[9] Fan, X., Fett, W. F., Mitchell, B. W., “Effect of negative air ions on Escherichia coli ATCC 25922 inoculated onto mung bean seed and apple fruit”, Journal of food protection, 70(204). 8. 2007.
[10] Soyka F, The ion effect, Bantum,Premium,U.S., 1991.
[11] Reilly T., Stevenson I., An investigation of the effects ofnegative air ions on responses to submaximal exercise at different times of day, Journal Human Ergol, 22(1)1-9, 1993.
[12] Combination of Engineering Physics and Modern Scientific Management in High Technology Achievements, Scientific Journal of Pure and Applied Sciences, 4(2), 39-43, 2015.
[13] Combination of Air Ionization and Engineering Physics Methods for Optimization Agroindustry, Scientific Journal of Review, 4(1), 7-9, 2015.
Cite This Article
  • APA Style

    Arezu Jahanshir. (2015). Applications to Engineering Physics for Reducing Air Pollution. Science Innovation, 3(6), 117-120. https://doi.org/10.11648/j.si.20150306.19

    Copy | Download

    ACS Style

    Arezu Jahanshir. Applications to Engineering Physics for Reducing Air Pollution. Sci. Innov. 2015, 3(6), 117-120. doi: 10.11648/j.si.20150306.19

    Copy | Download

    AMA Style

    Arezu Jahanshir. Applications to Engineering Physics for Reducing Air Pollution. Sci Innov. 2015;3(6):117-120. doi: 10.11648/j.si.20150306.19

    Copy | Download

  • @article{10.11648/j.si.20150306.19,
      author = {Arezu Jahanshir},
      title = {Applications to Engineering Physics for Reducing Air Pollution},
      journal = {Science Innovation},
      volume = {3},
      number = {6},
      pages = {117-120},
      doi = {10.11648/j.si.20150306.19},
      url = {https://doi.org/10.11648/j.si.20150306.19},
      eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.si.20150306.19},
      abstract = {Taking advantage of modern technology of the macro ionization of air in the air conditioning systems in order to promote the industrial air conditioning systems can be an appropriate way to resolve industrial centers and hospital's pollution, and also resolve monitoring of air in the urban tunnels. Breathing space around us is a mixture of particles and neutral and charged molecules, so by looking back at industrial achievements of tools and instruments of the air conditioners, electrical discharge method is practical and appropriate. In addition to refining of air pollutants, there is also the possibility of removing germs. Macro Air Ionization Technology (MAIT) in the industrial, hospital and urban tunnels is one of the offering methods of increasing healthy air as usual methods in environment. MAIT is a hi-tech equipment for improving air. One of these technologies is Negative Air Ionization Technology (NAIT). In the NAIT equipment air molecules after ionization change Negative Ion Concentrations in the room, tunnels and sheds. The negative ion molecules especially oxygen, will provide a healthy environment for plants growth process. Using NAIT, anions have the ability to conquest the microbes and microorganism. According to the performed research, utilizing the air ventilation modern technologies, have an efficient effect on the quantity and quality of important place as hospitals. For this reason, negative ion injections by MAIT into the air could be a part of research policies in developing and least developing countries for effective exploitation and correction of the Health and Safety Executive (HSE) conditions, as it was the part of basic research policies in last 40 years in developed countries. In this paper, we try to introduce hi-tech MAIT equipment based on corona discharge method.},
     year = {2015}
    }
    

    Copy | Download

  • TY  - JOUR
    T1  - Applications to Engineering Physics for Reducing Air Pollution
    AU  - Arezu Jahanshir
    Y1  - 2015/10/14
    PY  - 2015
    N1  - https://doi.org/10.11648/j.si.20150306.19
    DO  - 10.11648/j.si.20150306.19
    T2  - Science Innovation
    JF  - Science Innovation
    JO  - Science Innovation
    SP  - 117
    EP  - 120
    PB  - Science Publishing Group
    SN  - 2328-787X
    UR  - https://doi.org/10.11648/j.si.20150306.19
    AB  - Taking advantage of modern technology of the macro ionization of air in the air conditioning systems in order to promote the industrial air conditioning systems can be an appropriate way to resolve industrial centers and hospital's pollution, and also resolve monitoring of air in the urban tunnels. Breathing space around us is a mixture of particles and neutral and charged molecules, so by looking back at industrial achievements of tools and instruments of the air conditioners, electrical discharge method is practical and appropriate. In addition to refining of air pollutants, there is also the possibility of removing germs. Macro Air Ionization Technology (MAIT) in the industrial, hospital and urban tunnels is one of the offering methods of increasing healthy air as usual methods in environment. MAIT is a hi-tech equipment for improving air. One of these technologies is Negative Air Ionization Technology (NAIT). In the NAIT equipment air molecules after ionization change Negative Ion Concentrations in the room, tunnels and sheds. The negative ion molecules especially oxygen, will provide a healthy environment for plants growth process. Using NAIT, anions have the ability to conquest the microbes and microorganism. According to the performed research, utilizing the air ventilation modern technologies, have an efficient effect on the quantity and quality of important place as hospitals. For this reason, negative ion injections by MAIT into the air could be a part of research policies in developing and least developing countries for effective exploitation and correction of the Health and Safety Executive (HSE) conditions, as it was the part of basic research policies in last 40 years in developed countries. In this paper, we try to introduce hi-tech MAIT equipment based on corona discharge method.
    VL  - 3
    IS  - 6
    ER  - 

    Copy | Download

Author Information
  • Department of Engineering Physics, Buein Zahra Technical University, Qazvin, Iran

  • Sections